In the know Getting to grips with... harmonic distortion 30 | SEPTEMBER 2016 | WWT | www.wwtonline.co.uk companies must re-examine every aspect of their operations to ensure systems run as efficiently as possible. This includes tackling existing or suspected cases of harmonic distortion. Harmonic distortion may or may not create a problem. It is possible to have harmonics present but experience no adverse effects. However, as harmonic levels increase, the likelihood of experiencing problems also increases. What can be done to mitigate harmonic distortion? The good news is that although harmonic distortion can be difficult to diagnose, it is relatively easy to fix. As already outlined, drives are one of several types of non-linear equipment that can create harmonics. However, what is not widely known is that they also provide the remedy. There are three basic ways to rectify harmonics: reduction, diversion or cancellation. Reduction is achieved by adding inductance or an active rectifier. The most basic technique is to use AC line reactors, usually known as chokes, fitted inside or outside the drive. With a correctly sized AC/DC choke in an ordinary six-pulse drive, harmonics levels can be substantially reduced. The objective is to reduce harmonics to a level where they no longer cause a problem. Diversion involves using a passive filter to divert harmonics away from the affected equipment. This method has few application areas as well as several drawbacks. For instance, it increases voltage and heat loss and reduces power factor. Cancellation has previously been achieved by using a 12- or 24-pulse drive. The total harmonic load is divided between several isolated sources sharing a common primary supply via an input transformer. This method is now only used if the required transformers are already on site. A more modern approach to cancellation is to use either a low harmonic variable-speed drive (VSD) or a closed loop active filter. A low harmonic VSD cancels the harmonics within the VSD itself. A closed loop active filter injects an 'anti' harmonic that reduces harmonic current to zero. Is it possible to prevent harmonics from occurring in the first place? With the occurrence of harmonic distortion set to rise, water companies are increasingly taking steps to keep harmonic distortion within legal limits. Examples include Southern Water, which installed a combination of 90 low harmonic and 6-pulse drives at a new wastewater treatment plant in Sussex to minimise the harmonics that would be produced by the large motors employed in the pumping stations. But it's not only new sites that are at risk. Water companies also need to take appropriate steps to ensure harmonics stay within legal limits when installing new equipment at an existing site. In the case of VSDs, there is reason to be extra careful, as an individual site can have many of these installed. When adding further drives at a site, the total harmonic load should always be considered. What is the legal position regarding harmonic distortion? The maximum level of harmonic distortion allowed on the electricity network is controlled by Engineering Recommendation G5/4-1. Don't be misled by the word 'recommendations', however. G5/4 is a legal requirement that all electricity users must comply with. New installations that are not compliant can be refused permission to connect to the network. What's the next step? Whether you think you might have a harmonics problem, or you want to take action to avoid a problem from occurring, speak to your drives' manufacturer about a harmonic survey. An engineer will visit your site and install monitoring equipment. The gathered data will be analysed to determine the level of harmonic distortion at the site. If necessary, your vendor can discuss solutions to mitigate existing problems, or recommend steps to safeguard against a problem occurring in the future. Keeping harmonics and their damaging effects in check should be a priority for water utilities

Articles in this issue

Links on this page

Archives of this issue

view archives of Water & Wastewater Treatment - WWT September 2016