Network

Network Sept 2016

Issue link: https://fhpublishing.uberflip.com/i/721278

Contents of this Issue

Navigation

Page 20 of 39

NETWORK / 21 / SEPTEMBER 2016 N etwork asset and operations leaders will be all too familiar with the pressures on industry today to do more with their existing asset fleet, minimise capital expenditure and, at the same time, uphold the highest standards of safety. This is quite a challenge when the majority of big assets like transformers are at the end of their expected lifespan and when demand for power is changing in myriad ways. As network operators seek to balance these pressures, asset Fluid movement risk mitigation is becoming an essential discipline and no stone can be le• unturned when seeking ways to extend asset life, increase asset reliability and reduce the lifetime cost of new assets. With this challenge in mind, a white paper was recently published by M&I Materials to explore current and future risks to power utility transformers and the scope for countering these by switching out conventional mineral oil-based transformer fluids for synthetic organic or natural ester fluids – the former of which M&I is, unsurprisingly, a manufacturer under its Midel brand. Eliminate fire risk Reviewing common causes of transformer failure, M&I's white paper identifies a range of electrical, mechanical and thermal issues which can lead to costly unplanned outages. The risk of transformer fires is closely linked to many of these issues which have route causes including lightening/ power surges, overloading and failure of external transformer components which can cause ignition of the bulk oil in the transformer tank. Such fires can be catastrophic, destroying assets and posing a risk to the surrounding environment. They also clearly put people at risk and compromise performance against key service metrics. The main reason why transformer fires tend to be so destructive, is the flammable nature of transformer fluids, used as dielectric and cooling agents. These hydrocarbon- based oils have relatively low flash points and once ignited, burn vigorously. Esters meanwhile, which have been applied in transformers of up to 433Kv, have much higher flash and fire points (see table). As such, they It's time to change conventional thinking about transformer fluids and realise opportunities to mitigate asset risk, argues a new white paper. ASSET RISK essentially eliminate the risk of transformer fires – at least as a consequence of fluid ignition. Perform in spite of water ingress Another common cause of transformer failure is water ingress which degrades cellulose insulation paper and mineral oil dielectrics. As little as one part water in 40,000 parts oil can reduce breakdown voltage by 50% at ambient temperature according to M&I's paper. Using esters can solve both problems. There is evidence to suggest that insulating paper will have a 20-25% longer lifespan if submersed in an ester. In addition, esters themselves can absorb very high volumes of water before their performance is compromised. Realise lifetime asset cost reductions There's no denying that esters are more expensive than traditional mineral oils – and they come with additional costs since a move away from conventional dielectrics and coolants inevitably comes with transformer redesign work. However, M&I insists that by removing the need for external fire suppression systems and reducing the amount of transformer containment needed, transformers using ester fluids will return significant totex savings. They are also faster to install and bring online. While a wholesale switch to ester fluids for transformers is unlikely, it's clear that changing to these fire resistant fluids has a strong business case for transformers in urban environments or challenging environmental conditions and for transformers which are likely to be put under unusual stress and regularly run at high temperature. Fluid Flash point Fire point Mineral oil 150°C 170°C Synthetic organic ester 260°C 316°C Natural ester 260°C 350°C

Articles in this issue

Archives of this issue

view archives of Network - Network Sept 2016